Investigations on the linearity of indirect effects with different methods
- verfasst von
- E. Gockenbach, C. D. Ritschel, L. Jung, J. L.Ter Haseborg
- Abstract
The tests were carried out on a carbonfibre reinforced structure with a number of wires with different kind of installation. The peak value of the current impulses ranges from 20 κA up to 200 κA and the comparison shows, that a reasonable linearity exists for carbonfibre reinforced material and that the deviations are always on the save side. The verification of the linearity has been checked then by the so called low-level method. This method uses the transfer function of the whole test arrangement, with the current impulse as the excitation signal and the induced voltage on the wires as the response signal. Also the transfer function shows a good linearity of the system.
- Organisationseinheit(en)
-
Fachgebiet Hochspannungstechnik und Asset Management (Schering-Institut)
- Externe Organisation(en)
-
Technische Universität Hamburg (TUHH)
- Typ
- Konferenzaufsatz in Fachzeitschrift
- Journal
- SAE Technical Papers
- ISSN
- 0148-7191
- Publikationsdatum
- 1999
- Publikationsstatus
- Veröffentlicht
- Peer-reviewed
- Ja
- ASJC Scopus Sachgebiete
- Fahrzeugbau, Sicherheit, Risiko, Zuverlässigkeit und Qualität, Umweltverschmutzung, Wirtschaftsingenieurwesen und Fertigungstechnik
- Elektronische Version(en)
-
https://doi.org/10.4271/1999-01-2384 (Zugang:
Unbekannt)