Niayesh K, Mohammadi M, Farahani M, Gockenbach E. Degradation of Oil Impregnated Paper Film Insulation under Influence of Repetitive Fast High Voltage Impulses. 2013.
Mehr...
Pham DAK, Pham TMT, Borsi H, Gockenbach E. A new method for purposes of failure diagnostics and FRA interpretation applicable to power transformers. IEEE Transactions on Dielectrics and Electrical Insulation. 2013 Dez;20(6):2026-2034. 6678850. doi: 10.1109/TDEI.2013.6678850
Mehr...
Pham TMT, Pham DAK, Kazemi A, Borsi H, Gockenbach E. Frequency response interpretation of a delta winding in transformer bulk in low and mid frequency range. 2013.
Mehr...
Saadati H, Shayegani Akmal AA, Borsi H, Gockenbach E. Partial Discharge of Polymeric Insulators Under Artificial Pollution. 2013.
Mehr...
Werle P. Oil Diagnosis on Practical Examples. 2013.
Mehr...
Werle P. Reparatur und Prüfung von Transformatoren vor Ort. 2013.
Mehr...
Zhang X, Gockenbach E. Determination of the thermal aging factor for life expectancy of 550 kV transformers with a preventive test. IEEE Transactions on Dielectrics and Electrical Insulation. 2013 Dez 11;20(6):1984-1991. 6678845. doi: 10.1109/TDEI.2013.6678845
Mehr...
Zhang X, Gockenbach E, Liu Z, Chen H, Yang L. Reliability estimation of high voltage SF6 circuit breakers by statistical analysis on the basis of the field data. Electric power systems research. 2013 Jun 14;103:105-113. Epub 2013 Jun 14. doi: 10.1016/j.epsr.2013.04.014
Mehr...
Zheng J, Zhang X, Gockenbach E, Kuhnke M, Yuan X, You YM et al. Consideration of Acquisition Cost in Life Cycle Cost of High Voltage SF6 Insulated Substations. in 18th International Symposium on High Voltage Engineering, ISH 2013. 2013
Mehr...
Behjat V, Vahedi A, Setayeshmehr A, Borsi H, Gockenbach E. Sweep frequency response analysis for diagnosis of low level short circuit faults on the windings of power transformers: An experimental study. International Journal of Electrical Power and Energy Systems. 2012 Nov;42(1):78-90. doi: 10.1016/j.ijepes.2012.03.004
Mehr...
Farahani M, Gockenbach E, Borsi H. Untersuchungen zum Zusammenhang zwischen der Durchschlagspannung und den Diagnostischen Messungen an einem Isoliersystem für rotierende elektrische Maschinen. 2012.
Mehr...
Farhadinejad Z, Ehsani M, Momenbellah S, Saei Shirazi MM, Alavi SMB, Borsi H. An investigation of thermal, physical, and electrical properties and morphological behavior on nanoepoxy composite insulation. IEEE Transactions on Nanotechnology. 2012;11(5):957-963. 6243211. doi: 10.1109/TNANO.2012.2209458
Mehr...
Gockenbach E. Einzug der digitalen Messwerterfassung in die Hochspannungsprüftechnik. Elektrotechnik und Informationstechnik. 2012 Sep 27;129:342-348. doi: 10.1007/s00502-012-0033-0
Mehr...
Gockenbach E. High voltage and high current test techniques. in Proceedings of 2012 IEEE International Conference on Condition Monitoring and Diagnosis, CMD 2012. 2012. S. 91-94. 6416288. (Proceedings of 2012 IEEE International Conference on Condition Monitoring and Diagnosis, CMD 2012). doi: 10.1109/CMD.2012.6416288
Mehr...
Gockenbach E, Werle P. High-Voltage On-Site Testing with Partial Discharge Measurement. ELECTRA. 2012.
Mehr...
Gockenbach E, Zhang X, Liu Z, Chen H, Yang L. Life Time Prediction of Power Transformers with Condition Monitoring. 2012.
Mehr...
Gockenbach E. UHV technology. Elektrotechnik und Informationstechnik. 2012 Aug 23;129:192-199. doi: 10.1007/s00502-012-0023-2
Mehr...
Gratz O, Gockenbach E, Borsi H. Untersuchung der Trocknungs- und Imprägniereigenschaften von Zellulosepapierisolationen mittels dielektrischer Diagnoseverfahren im Frequenz- (FDS) und Zeitbereich (PDC). 2012.
Mehr...
Mirzaei HR, Akbari Azirani A, Zanjani M, Miralikhani K, Gockenbach E, Borsi H. Investigating suitable positions in power transformers for installing UHF antennas for partial discharge localization. in Proceedings of 2012 IEEE International Conference on Condition Monitoring and Diagnosis, CMD 2012. 2012. S. 625-628. 6416223. (Proceedings of 2012 IEEE International Conference on Condition Monitoring and Diagnosis, CMD 2012). doi: 10.1109/CMD.2012.6416223
Mehr...
Mirzaei HR, Akbari Azirani A, Zanjani M, Gockenbach E, Borsi H. Investigating the partial discharge electromagnetic wave propagation in power transformers considering active part characteristics. in Proceedings of 2012 IEEE International Conference on Condition Monitoring and Diagnosis, CMD 2012. 2012. S. 442-445. 6416173. (Proceedings of 2012 IEEE International Conference on Condition Monitoring and Diagnosis, CMD 2012). doi: 10.1109/CMD.2012.6416173
Mehr...