Publications of High Voltage Engineering and Asset Management Section

Schering-Institute

2002


Akbari A, Werle P, Borsi H, Gockenbach E. A continuous parameter high frequency model based on travelling waves for transformer diagnostic purposes. Conference Record of IEEE International Symposium on Electrical Insulation. 2002;154-157. doi: 10.1109/ELINSL.2002.995901
Akbari A, Werle P, Borsi H, Gockenbach E. Transfer function-based partial discharge localization in power transformers: A feasibility study. IEEE Electrical Insulation Magazine. 2002 Sept;18(5):22-32. doi: 10.1109/MEI.2002.1044318
Akbari Azirani A, Werle P, Borsi H, Gockenbach E. A New Method for On-line Measurement and Evaluation of Partial Discharge in Power Transformers Using Fibre-Optic Transmission. 2002.
Borsi H. Möglichkeiten der Diagnose von Leistungstransformatoren vor Ort. 2002.
Borsi H. Möglichkeiten der Isolationsdiagnose durch Bewertung der dielektrischen Antwort von Isoliersystemen. 2002.
Borsi H. Possibilities of the Diagnosis of Power Transformers on Site. 2002.
Farahani M, Borsi H, Gockenbach E. Experience with partial discharge, dissipation factor and recovery voltage measurements for the evaluation of insulation systems of high voltage rotating machines. Conference on Electrical Insulation and Dielectric Phenomena (CEIDP), Annual Report. 2002;454-457.
Farahani M, Borsi H, Gockenbach E, Bethge B, Kaufhold M, Jung J. Investigations on characteristic parameters to determine the actual status of the insulation system of high voltage rotating machines. 2002.
Fofana I, Wasserberg V, Borsi H, Gockenbach E. Challenge of mixed insulating liquids for use in high-voltage transformers, Part 1: Investigation of mixed liquids. IEEE Electrical Insulation Magazine. 2002 May;18(3):18-31. doi: 10.1109/MEI.2002.1014964
Fofana I, Wasserberg V, Borsi H, Gockenbach E. Challenge of mixed insulating liquids for use in high-voltage transformers, Part 2: Investigations of mixed liquid impregnated paper insulation. IEEE Electrical Insulation Magazine. 2002 Jul;18(4):5-16. doi: 10.1109/MEI.2002.1019901
Fofana I, Wasserberg V, Borsi H, Gockenbach E. Preliminary investigations for the retrofilling of Perchlorethylene based fluid filled transformer. IEEE Transactions on Dielectrics and Electrical Insulation. 2002 Feb;9(1):97-103. doi: 10.1109/94.983892
Gockenbach E. Evaluation of Lightning Impulse Voltages Based on Experimental Results. ELECTRA (Print). 2002.
Gockenbach E. Grundsätzliche Untersuchungen zum Durchschlagverhalten kunststoffisoliertet Kabel bei Spannungen unterschiedlicher Frequenz. 2002.
Gockenbach E. Möglichkeiten und Grenzen der Diagnostik von Isolierstoffen in elektrischen Betriebsmitteln. 2002.
Gockenbach E. Monitoring von Kabelsystemen - Möglichkeiten und Wirtschaftlichkeit. 2002.
Gockenbach E, Borsi H. Performance and new application of ester liquids. In Proceedings of 2002 IEEE 14th International Conference on Dielectric Liquids: ICDL 2002 (Cat. No.02CH37319). IEEE. 2002. p. 203-206 doi: 10.1109/ICDL.2002.1022730
Gockenbach E. Practical Results concerning the prediction of Damaging Effects for Lightning Impulses (LEMP). 2002.
Gockenbach E. Review of Material Advance for High Voltage Electrical Machines. 2002.
Kotte R, Gockenbach E, Borsi H. Influence of the cure parameters on the partial discharge behavior of cast resins. Conference Record of IEEE International Symposium on Electrical Insulation. 2002;387-390.
Krins M, Reuter M, Borsi H, Gockenbach E. Breakdown and flashover phenomena related to the presence of high absolute water contents in clean and carbonized transformer oil. Conference on Electrical Insulation and Dielectric Phenomena (CEIDP), Annual Report. 2002;252-255.

Annual Reports and Newsletters of High Voltage Technology and Asset Management Section