Publications of High Voltage Engineering and Asset Management Section

Schering-Institute

2009


Setayeshmehr A, Abdallah J, Akbari A, Borsi H, Gockenbach E. Evaluating of water exchange between oil and paper in transformers under operating conditions. 2009.
Setayeshmehr A, Borsi H, Gockenbach E, Fofana I. On-line monitoring of transformer via transfer function. In 2009 IEEE Electrical Insulation Conference, EIC 2009. 2009. p. 278-282. 5166357. (2009 IEEE Electrical Insulation Conference, EIC 2009). doi: 10.1109/EIC.2009.5166357
Sorgatz W, Werle P. Isolierölmonitoring – einfacher und besser. EW – Magazin für die Energiewirtschaft. 2009;108(16).
Szczechowski J, Werle P. Experiences with On-Site Testing of Power Transformers – TrafoSiteTesting. 2009.
Victoria R, Borsi H, Gockenbach E. Flashover Performance of Insulation Surfaces under Combined DC Stress and Air Flow. 2009.
Wasserberg V, Werle P. Selection and Maintenance of an adequate Transformer Insulation System. 2009.
Werle P, Lukas M. Einsatz mobiler Hochspannungsprüfsysteme für Leistungstransformatoren Beispiele aus der Praxis. 2009.
Werle P. Green Retrofit –umweltfreundliche Überholungs- und Reparaturkonzepte. 2009.
Werle P, Steiger M, Szczechowski J, Krüger M, Kraetge A, Koch M et al. Hochspannungsprüfungen an Leistungstransformatoren vor Ort. EW – Magazin für die Energiewirtschaft. 2009;108(4).
Werle P, Lorin P, Eklund L. Innovative Asset Management Using MTMP and TrafoSiteTesting. 2009.
Werle P. Möglichkeiten der Instandhaltung und Zustandsverbesserungen von Leistungstransformatoren. 2009.
Zhang X, Zhang J, Gockenbach E, Borsi H. Life management of SF6 circuit breakers based on monitoring and diagnosis. IEEE Electrical Insulation Magazine. 2009;25(3):21-29. doi: 10.1109/MEI.2009.4976899
Zhang X, Gockenbach E, Borsi H. Monitoring and Diagnosis for Life Management of Cable Systems. 2009.
Zhang X, Zhang J, Gockenbach E. Reliability centered asset management for medium-voltage deteriorating electrical equipment based on Germany failure statistics. IEEE transactions on power systems. 2009 May;24(2):721-728. doi: 10.1109/TPWRS.2009.2016533

2008


Akbari A, Setayeshmehr A, Borsi H, Gockenbach E. A software implementation of the Duval triangle method. Conference Record of IEEE International Symposium on Electrical Insulation. 2008;124-127. 4570294. doi: 10.1109/ELINSL.2008.4570294
Borsi H, Gockenbach E, Dolata B. Ester fluids as alternative for mineral based transformer oil. In 2008 IEEE International Conference on Dielectric Liquids, ICDL 2008. 2008. 4622541 doi: 10.1109/ICDL.2008.4622541
Bouaïcha A, Fofana I, Farzaneh M, Beroual A, Setayeshmehr A, Borsi H et al. Controle non destructif des isolations electriques par spectroscopie dielectrique des bornes de traversee. Revue de l'Electricité et de l'Électronique. 2008.
Farahani M, Gockenbach E, Borsi H, Kaufhold M. Behavior of a machine insulation system during accelerated aging tests. Conference Record of IEEE International Symposium on Electrical Insulation. 2008;404-407. 4570359. doi: 10.1109/ELINSL.2008.4570359
Gockenbach E, Borsi H. Condition monitoring and diagnosis of power transformers. In Proceedings of 2008 International Conference on Condition Monitoring and Diagnosis, CMD 2008. IEEE Computer Society Press. 2008. p. 894-897. 4580427. (Proceedings of 2008 International Conference on Condition Monitoring and Diagnosis, CMD 2008). doi: 10.1109/CMD.2008.4580427
Gockenbach E, Borsi H. Natural and synthetic ester liquids as alternative to mineral oil for power transformers. In 2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, CEIDP 2008. 2008. p. 521-524. 4772928. (Annual Report - Conference on Electrical Insulation and Dielectric Phenomena, CEIDP). doi: 10.1109/CEIDP.2008.4772928

Annual Reports and Newsletters of High Voltage Technology and Asset Management Section